  1. Groth Corp. Model 8110 Back Pressure Check Valve

    Groth Corp. Model 8110 Back Pressure Check Valve

    The Model 8110 Back Pressure Check Valve is used specifically in low pressure gas control lines where minimum pressure drops and maximum flow capacity are required. Model 8110 valves are built of corrosion resistant trim. Furnished standard in aluminum with free swinging aluminum pendulum type pallet. By removing the cover, easy access is provided for quick inspection and maintenance. Model 8110 check valves should be installed in your low pressure line downstream of meters, regulators, and other gas control devices that may be otherwise damaged by an accidental reversal of the pressure in the system due to pressure waves from a flashback or similar disturbance.
  2. Groth Corp. Model 8170 Well Type Manometer

    Groth Corp. Model 8170 Well Type Manometer

    The Groth Model 8170 Well-Type Manometer is a direct reading, single column type pressure gauge providing accurate pressure readings, positive, negative, or differential. It is used to indicate gas pressure in lines from the digester and those leading to utilities and waste gas burners. The Groth unit may be used indoors or outdoors and is designed to be mounted almost anywhere for convenience. The Groth Model 8170 may be wall mounted or panel mounted. Any number of tubes may be mounted side by side on a common panel. A solid acrylic assembly protects the shatter-proof tube and the scale against dust, dirt, and rain. Groth manometers have no hidden wells or packing glands, and so are leak proof. The tube can be filled with a red oil-type liquid. The large-type inch scale is easy to read. Heavy aluminum construction and durable coating provides a long lasting product which is designed for easy cleaning and maintenance.
  3. Groth Corp. Model 8180 Sight Glass

    Groth Corp. Model 8180 Sight Glass

    Designed to be installed on the Model 8330 Sediment Trap, the Groth Model 8180 Sight Glass provides immediate, simple indication of fluid level in a sediment trap.
  4. Groth Corp. Model 8330 Sediment Trap

    Groth Corp. Model 8330 Sediment Trap

    The Groth Model 8330 Sediment Trap is for use in low pressure gas lines to remove sediment and/or condensate from a "wet" gas. These traps are normally installed to provide additional safety by removing almost all of the solids and liquid from the gas stream. Groth's design creates a combination of internal centrifugal force and a drop in the velocity of the gas which contributes to the successful removal of solids and liquids.
  5. Groth Corp. Model 8400A Pressure Relief & Flame Trap Assembly (7628 & 8860)

    Groth Corp. Model 8400A Pressure Relief & Flame Trap Assembly (7628 & 8860)

    The Groth Model 8400A Pressure Relief and Flame Trap Assembly accomplishes two purposes. It will maintain a predetermined back pressure in order that only surplus gas is flared and inhibits a possible flame flashback of the flare into the combustible fuel control system.
  6. Groth Corp. Model 8450/8480 Drip Trap - Automatic

    Groth Corp. Model 8450/8480 Drip Trap - Automatic

    Groth drip traps may be easily attached to a Groth Sediment Trap for extra efficiency or installed for collection and safe removal of liquids from low points in gas control lines. The Groth Model 8450 is an automatic design with a unique float operated valve. Also available: Groth Model 8480 (automatic), for high pressure (up to 60 PSIG) operation.
  7. Groth Corp. Model 8460/8470 Drip Trap - Manual

    Groth Corp. Model 8460/8470 Drip Trap - Manual

    Groth drip traps may be easily attached to a Groth Sediment Trap for extra efficiency or installed for collection and safe removal of liquids from low points in gas control lines. The Groth Model 8460 is a manually operated design for pressures up to 5 PSIG. Also available: the Groth Model 8470 for higher pressures (up to 60 PSIG).
  8. Groth Corp. Model 8490/8491 Electrically Actuated Drip Trap

    Groth Corp. Model 8490/8491 Electrically Actuated Drip Trap

    The Model 8490 electrically operated drip trap combines the reliability of a rotating disc manual drip trap with the convenience of an automatic drip trap. It can be controlled by an integral cycle timer, a Groth remote sequence controller, or the owner's master control system.
  9. Groth Corp. Model 8500A Flame Trap Assembly (7628 & 8530)

    Groth Corp. Model 8500A Flame Trap Assembly (7628 & 8530)

    The Groth Model 8500A contains a horizontal flame arrester and a thermal operated shut-off valve. This unit is generally installed in combustible vapor lines. They are also installed in a line to gas utilization equipment, as close as possible to the source of combustion.
  10. Groth Corp. Model 8530 Thermal Operated Shut-off Valve

    Groth Corp. Model 8530 Thermal Operated Shut-off Valve

    The Groth Model 8530 Thermal Operated Shut-off Valve is supplied as part of the 8500A Flame Trap Assembly. See the 8500 literature for technical specifications.